Schema Versioning and Generations

Schema Versions

As products (applications and services) evolve, they will require new and/or different data organization. As the data organization is defined in schemas, schemas must change to support the newer products. This leads to the need to clearly version schemas.

Schema versioning should not be confused with data versioning. Data will be changed very frequently by users. Schemas will change less frequently, only as improved products that require new data organization are released.

Need for Schema Upgrade Strategy

Most iModels are accessed by multiple products. Products will synchronize through iModelHub. The data that products store will be organized by a single (versioned) set of schemas.

One potential strategy to ensure that all the products can work with the schemas in an iModel is limit the products used to the subset of products that are written for the exact versions of the schemas that are in the iModel. If there is a desire to update a product and that update requires newer schemas, then all of the products accessing the iModel are updated simultaneously. This quickly becomes an untenable strategy when more than a very small number of applications and services are used. For that reason, our schema evolution strategy needs to accommodate non-aligned product releases.

The BIS schema upgrade strategy is based on the concept of Generations which are closely related to Minor Schema Upgrades and Major Schema Upgrades.

Some services that do not directly work with iModels will use BIS semantics. These services will also benefit from versioning strategy described in this section.

EC Schema Versioning

There are clear EC schema versioning rules that are based on the repercussion of changes made during a schema upgrade.

Minor Schema Upgrades

Minor schema upgrades are schema changes that don’t break compatibility with applications written for the previous schema.

Minor schema upgrades can ONLY include:

  • The addition of optional classes.
  • The addition of a class in the middle of a class hierarchy
  • The addition of optional properties.
  • The addition of Kinds of Quantities.
  • The addition and deletion of Property Categories.
  • Loosening of constraints
    • Class modifier changed from Sealed to None
    • Making a relationship constraint polymorphic or lowering the minimum or increasing the maximum cardinality
  • Changes to items that don’t affect code (or meaning), such as:
    • display label, role label or description changes
    • presentation unit or format changes (either in a KindOfQuantity definition or by switching a property to a different KindOfQuantity with the same persistence unit)
    • any other changes that just affect presentation.

Minor schema upgrades may NOT include:

  • The removal of classes.
  • The removal of properties.
  • The change of class definition (for example, changing the base class so the class no longer 'is' the original base class).
  • The change of property definition (for example, changing the type or changing the KindOfQuantity if it changes the persistence unit).
  • The change of relationship constraints or strength or narrowing the cardinality.

Major Schema Upgrades

Major schema upgrade can potentially break compatibility with applications written for the previous schema. Any schema change that does not qualify as minor is major. Some examples of changes that trigger a major schema change are:

  • Removal of a class.
  • Removal of a property.
  • Renaming of a class or property.
  • Changing of a base class in a way that makes the former parent class no longer a direct ancestor (currently any change in parent class is a major schema upgrade).
  • Changing the type of a property.
  • Changing relationship constraints or cardinality.

Schema Version Numbers

To be able to detect schema changes that are backward compatible for reading data, but not backward compatible for writing data, EC Schema version numbers have 3 parts

Digit Meaning Changes Imply
1st (read) Generation of the schema that guarantees (if digit matches) that newer schemas' data can be read by older software. No compatibility can be assumed for previous schema versions (breaks read and write logic)
2nd (write) Sub-generation of the schema that guarantees (if digit matches) that newer schemas' data can be written by older software. Additions have been made to the schema which break existing write logic (but not read logic)
3rd (minor) Least significant version number that increments with read/write compatible additions. Additions have been made to the schema, but they do not break existing schema read or write logic.

This 3-digit system is a little different from the standard 3-digit versioning strategy described at Semantic Versioning. This is due primarily due to Semantic Versioning pertaining to APIs and code instead of schemas.

The Middle Version Number

The second write version number is a bit difficult to understand - how does it correspond to a Major Schema Updates and Minor Schema Updates?

Effectively the second write version number is updated when a schema upgrade can be considered a major update for writers of the data, but is only a minor update for readers of the data.

For example, consider in schema 1 that we have a Student class that stores grades and has (double) properties:

  • Language
  • Math
  • Science
  • Music
  • Overall GPA (an average of the previous 4 properties)

If schema 2 adds to Student a double property Psychology, the meaning of Overall GPA changes slightly and hence, applications written for Schema 1:

  • Can still safely read all the values that were in schema 1
  • Cannot modify any values that were in schema 1 because they will likely set Overall GPA incorrectly.

Updating data for a schema update with a write version change usually requires some custom logic. This should not be surprising as the previous data was written by applications that are not write-compatible with the newer schema.

Examples of Write incompatible changes

  • Adding a Not Null or Unique constraint on a new property in an existing class
  • Adding a new Navigation Property with a Foreign Key constraint to an existing class

There are other examples of write incompatible changes which, however, are prohibited by the software because they would modify how EC content is mapped to the database (which is generally not allowed):

  • Adding a Not Null or Unique constraint to an existing property
  • Adding a new unique index to an existing class
  • Adding a Foreign Key constraint to an existing Navigation Property

Application Schema Compatibility Logic

The general logic for an application written for a particular version of a schema working with a repository that potentially has a different version of the schema would be:

  • If schema in the repository is newer (or same):
    • If first digit matches, app can safely read.
    • If first two digits match, app can safely write (and read).
    • If no digit matches, the schema is of a different generation and the application cannot do anything.
  • If schema in the repository is older:
    • If first two digits match, app can upgrade repository schema without breaking read or write for other apps.
    • If only first digit matches, app can upgrade repository schema, but upgrade will prevent some older apps from writing.
    • If no digit matches, the schema is of a different generation and the application cannot do anything.

BIS Generations

Major schema upgrades are eventually required in any evolving product or system. If every Domain was allowed to select when its major schema updates occurred, then – as BIS will have a large number of Domains – nearly every BIS release would contain some major schema updates.

To avoid the confusion of continual major schema updates, BIS Generations are defined and major schema updates are restricted.

BIS Generation

A BIS Generation consists of a series of releases during which major schema upgrades are not allowed for any Domain. As minor schema upgrades will not break application compatibility, any application based on the same BIS Generation can work together through an iModel.

The 3-digit schema version numbers of EC Schemas (Read.Write.Minor) allow two types of Major schema version to be defined. As an emergency outlet, it will be allowed to change the Write version number within a Generation, but this will be severely discouraged. To ensure that changes to the Write version number are taken seriously enough, OCTO review is recommended for any such Write changes.

It must be remembered that repositories can be updated from one Generation to the next Generation without loss of data. It is the individual applications that can only work with repositories from a single Generation.

Generation Schema Numbering

As BIS Generations are tightly aligned with major schema upgrades, it is natural to use the Generation number as the major schema version for all BIS Domains. The numbering for all schemas in a Generation is Generation.Write.Minor, where all the Generation numbers in a BIS repository match. The Write numbers will almost always all be 0. The Minor numbers can and will vary.


| Next: Schema Production Status |:---